Produktsuche
 
 


Nominalstrom
Messberich

Ipn (Apn)

Versorgung(V) Typische Genauigkeit
@ 25°C % von Ipn
Bandbreite (kHz) Einbau Technologie Serie
0.25 - 200 +/- 12...15 0.4 - 0.9% DC - 150 PCB C/L LA 25-200 -P
100 - 1000 +/- 15 1 - 1.35% DC - 50 Panel O/L HTA Traction
200- 500 +/- 12...24 0.6 - 0.9% DC - 100 Panel C/L LA 205 / 305 -S/ -T Traction
200 - 500 +/- 24 1% DC - 100 Split core C/L LA 200 / 500-SD
200 - 2000 +/- 12...24 0.2 - 0.4% DC - 150 Panel C/L LF Traction
300 - 400 +/-15

0.7 - 1%

DC - 50 Panel C/L LAC 300-S
350 - 500 +/- 15...+/- 24 0.5 - 0.6% DC - 100 Panel C/L LTC 350 - 500
250 - 4400 +/- 15..60
...+24
0.2 - 0.8% DC - 150 Panel C/L LT Traction
500 -1000 +/- 15... +/- 24 0.4 - 0.7% DC - 100 Panel C/L LTC 600 - 1000
500 - 3000 +/- 15 2.8% DC - 10 Panel O/L HTC
1000 +/- 15 1.2% DC - 10 Panel O/L HAR
4000 - 20000 +/- 15 1% DC - 3 Panel O/L HAZ
             
<20 A AC on
<3000 A DC
+/- 15 <5 % 10 - 3000Hz Panel Rogowski RA Interference Current Measurement
             
+/- 2 +/- 15 2.5 % 5 Panel Fluxgate C CD Differential Current Measurement

Die Angaben gelten nur als allgemeine Hinweise. Bitte beachten Sie das spezifische Datenblatt für jedes Produkt.

Strommessungen in Bahntechnik

Nominalstrom
Messberich

Ipn (A)

Versorgung(V) Typische Genauigkeit
@ 25°C % von
Ipn
Bandbreite (kHz) Einbau Technologie Serie
10 - 30 0...+24 1 DC...1 Panel / Rail
DN
C/L Points Conditions Monitoring (PCM)


Spannungsmessungen in Bahntechnik

Mit R1 Widerstand

Nominalstrom
Messberich

Ipn (Vpn)

Versorgung(V) Typische Genauigkeit
@ 25°C % von
Ipn
Bandbreite (kHz) Einbau Technologie Series
50 -2000 +/- 12...24 0.7 <13 Panel Isolation Amplifier AV 100-Voltage
50 - 2000 +/- 15...24 0.7 - 1.2 <10 Panel C/L LV 100-Voltage 1
85 - 1400 +/- 15...24 <0.375 <300 - 800 Panel Fluxgate C CV 3-Voltage
200 - 1200 +/- 12...15 0.8 - 0.9 <10 Panel C/L LV 25-Voltage
200 - 6400 +/- 15...24 0.8 - 2.5 <1 Panel C/L LV 200-AW/2/Voltage
2121 - 4242 +/- 15 & +/- 24 <1.4 <21 Panel Fluxgate C CV 4-Voltage
2500 - 4000 +/- 15...24 0.2 - 0.8 <10 Panel C/L LV 100-Voltage 2
1200 - 4200 +/- 13.5 ...26.4 0.4 <12 Panel Insulating Digital DV Voltage


Ohne R1 Widerstand

Nominalstrom
Messberich

Ipn (Vpn)

Versorgung(V) Typische Genauigkeit
@ 25°C % von
Ipn
Bandbreite (kHz) Einbau Technologie Serie
10 mA
(10 - 500V)
+/- 12...15 0.8 - 1 <10 PCB C/L LV 25-P
10 - 210 mA
(100 - 2500V)
+/- 12...24 0.7 <10 Panel C/L LV 100
20 mA
(100 - 2500V)
+/- 15...24 0.6 <6 Panel C/L LV 200-AW/2